Extrusion 40x120

PIL 4012

Application

universally applicable, e.g. for

  • roller conveyor
  • cable ducts
  • manual workstations
  • in- and outfeed conveyors
Article
Article
Extrusion 40x120, cut to length, tapped on both ends M6x15, M8x50
Add to basket

Extrusion 40x120, cut to length, tapped on both ends M6x15, M8x50

PIL4012SNN

Not available
Extrusion 40x120, stock length 6050mm
Add to basket

Extrusion 40x120, stock length 6050mm

PIL4012NNN

Not available
Extrusion 40x120, 24 units, stock length 6050mm
Add to basket

Extrusion 40x120, 24 units, stock length 6050mm

PIL4012PAC

Not available
Extrusion 40x120, cut to length, tapped on both ends M6x15, M8x50
PIL4012SNN
Unit price:
Total:
Extrusion 40x120, stock length 6050mm
PIL4012NNN
Total:
Extrusion 40x120, 24 units, stock length 6050mm
PIL4012PAC
Total:

Product Information

Material

clear anodized aluminum

Section modulus

Wx: 27.6cm3

Section modulus

Wy: 6.8cm3

Geometrical moment of inertia against x

Ix: 182.2cm4

Geometrical moment of inertia against y

Iy: 19.3cm4

Geometrical moment of inertia against torsion

It: 1.2cm4

Cross sectional area

A: 1108.8mm2

Weight/Meter

3.050 kg

Load types


Force impact

Distributed Distributed
Central Central

Extrusion alignment

Horizontal Horizontal
Vertical Vertical

Load case

Supported on both sides, distributed Supported on both sides
Clamped on both sides, distributed Clamped on both sides
Clamped on one side, distributed Clamped on one side

Calculation values


Force   F

N

Distance   L

mm

Calculation result


Deflection  f 0.00 mm
Bending stress  σ 0.00 N/mm²
Bending stress must not be greater than 50 N/mm²!
The deflection should not exceed 3 mm.
The calculations do not contain any certainty!

Summary


Profile: 40x120 Force impact: Distributed Extrusion alignment: Horizontal Load case: Supported on both sides Force  F : 0 N Distance  L : 0 mm

CAD data

To the CAD data

Application solutions